List of safety standards TEX series certificated
TEX-E, TEX-ECEW3, TEX-ELZ
Organization | Requirements Standard No.(note 1) | Cert. No.(note 2) | Rating | Certificated product |
---|---|---|---|---|
UL | UL 2353 UL 1950/IEC 60950-1, Annex U (UL 1411,UL 60950-1) |
E206440,OBJT2 | 1000 Vrms Class B(note 3) |
TEX-E TEX-ELZ TEX-ECEW3 |
CSA (NRTL/C) |
CAN/CSA 60065-03 incl. AM1+AM2 ANSI/UL Std No. 60065-2013 CAN/CSA-C22.2 No. 60950-1-07+AM1, AM2 ANSI/UL 60950-1-2014 |
Master Contract 185274 (LR104155) |
1000 Vrms Class B |
TEX-E TEX-ELZ TEX-ECEW3 |
TUV Rheinland |
EN 60950-1:2006+A11+A1+A12+A2 IEC 60950-1:2005+A1+A2 DIN EN 60950-1:2011+A12 IEC 60065:2001+A1+A2 EN 60065:2002+A1+A11+A2+A12 |
T9251520 | 1000 Vrms Class B 500kHz |
TEX-E TEX-ELZ TEX-ECEW3 |
BSI | BS EN 60065: 2002 IEC 60065: 2001 BS EN 60950-1:2006 IEC 60950-1:2005 |
KM 36738 | 1000 Vrms Class E |
TEX-E |
NEMKO | EN 60065:2002;A1;A11;A2;A12 EN 60950-1:2006;A11;A1;A12;A2 |
P10212368/A5 | 1000 Vrms Class E |
TEX-E TEX-ELZ TEX-ECEW3 |
VDE | DIN EN 60950-1 (0805-1):2014-08; EN60950-1:2006+A11+A1+A12+AC+A2:2013 IEC60950-1:2005/AM1:2009/AM2:2013 DIN EN 60065 (VDE 0860):2015-11 EN 60065:2014 IEC 60065:2014(eight edition) IEC62368-1(ed.2) DIN EN 60601-1 (VDE 0750-1):2013-12 EN 60601-1/A1:2013-10 IEC 60601-1 (ed.3);am1 DIN EN 61558-1/A1 (VDE0570-1/A1):2009-11 EN 61558-1/A1:2009 IEC61558-1 (Second Edition) +A1:2009 DIN EN 61558-2-16 (VDE0570-2-16):2014-06 EN 61558-2-16:2009+A1:2013 IEC 61558-2-16:2009+A1:2013 |
6735 (TEX-E) 40032438 (TEX-ELZ) |
500kHz Class B 1000 Vrms (IEC 60950, IEC 60065, IEC62368) 1000 Vrms (IEC 60601, except for 600Vrms for Two MOPP) 600Vrms(IEC61558) |
TEX-E TEX-ELZ |
(note 1) TEX-E series is reinforced insulation wire which comply with clause 2.10.5.12, Annex U of IEC 60950-1 2nd edition and test voltage 3kVrms for 1min by clause 8.17, Annex H of IEC60065 7th edition. And TEX-E series also comply with 6kVrms for 1min in twist pair sample following to these standards.
(note 2) Numbering is subject to change following to the revision of the standard.
(note 3) UL requests wires to be evaluated following to the proper insulation system (UL1446/IEC61857) regardless the temperature resistivity of wires or parts when it is used above class A(105℃).
note TEX-E; standard type, TEX-ELZ; litz conductor type, TEX-ECEW3; self-bonding type
UL1446 insulation system
UL requests wires to be evaluated following to the proper insulation system (UL1446/IEC61857) regardless of the temperature resistivity of wires or parts itself when they are used above class A(105℃). The purpose of EIS is evaluating not wire itself but the endurance/life-time of wound component with chemical interaction.
Please note that EIS is neither the specification of TEX series nor guarantees of the performance of the wound components using our wires. And please kindly ensure evaluating actual component since the performance of TEX series is affected by the design and processing on customer side.
System Temperature / Model | System Holder | UL File No. | System designation |
---|---|---|---|
B (130℃) / TEX-E | Furukawa Electric | E230451 | FIS-B1, FIS-B3 |
Hitachi Chemical | E150003 | HIS-8A | |
P.LEO | E200050 | B97 | |
Sumitomo Bakelite | E209189 | SBI4.1 SBI4.2 |